Substations, wind and solar parks, batteries, inverters, smart meters and the vendor clouds that manage them.
Substations, wind and solar parks, batteries, inverters and smart meters are monitored and controlled remotely, often through vendor clouds. The energy transition multiplies the connected devices that keep the grid stable.
Operators face NIS2 and the KRITIS rules. Manufacturers of inverters, controllers and charging equipment face the CRA and the Radio Equipment Directive. Both have to show that remote control cannot be abused.
The attack paths we see most often in generation, grids and the devices connected to them.
Remote control
Many inverters and turbines are controlled through the manufacturer's cloud. One compromised platform reaches thousands of assets at once.
Communications
Remote sites depend on third-party networks. When these fail, monitoring and control are lost.
Substations
IEC 61850 and telecontrol protocols were designed for closed networks and need protection once they are connected.
Remote access
Service teams and contractors access parks and stations remotely, often with shared accounts.
Devices
Firmware vulnerabilities in inverters and battery controllers can affect grid stability when exploited at scale.
Metering
Meter gateways connect homes and businesses to the grid. In Germany their security is regulated by the BSI.
Corporate IT
Ransomware in the office forces precautionary shutdowns of systems that support operations.
Supply chain
Components and software from many vendors meet in one plant. A vulnerability in one product affects many sites.
Three documented cases from the energy sector. They show what happens when remote control is lost or abused.
December 2015, grid attack
On 23 December 2015, attackers took remote control of the SCADA systems of three Ukrainian distribution companies and opened breakers at substations. They had prepared for months, starting with phishing emails.
Impact
About 225,000 customers lost power for several hours. The attackers also overwrote device firmware and wiped systems to delay recovery, so operators had to run substations manually.
Sources: E-ISAC and SANS ICS analysis, March 2016; ICS-CERT
February 2022, satellite network attack
An attack on the KA-SAT satellite network, on the day Russia invaded Ukraine, disabled tens of thousands of modems across Europe. Enercon used this network to monitor and control wind turbines.
Impact
About 5,800 turbines with 11 GW of capacity could no longer be monitored or reset remotely. They kept producing power, but restoring the connections took weeks.
Sources: Enercon; Viasat; Reuters; AFP
March 2022, ransomware
The wind turbine manufacturer detected an intrusion on 31 March 2022 and shut down IT systems across multiple locations and business units as a precaution. The Conti ransomware group later claimed the attack.
Impact
The turbines kept running, but Nordex had to switch most of its fleet to alternative remote control services while its systems were restored.
Sources: Nordex press releases, April 2022; Infosecurity Magazine; ISMG
Six building blocks that keep generation and grids controllable, for operators and manufacturers.
1
Every site, device and remote connection is known, including vendor clouds.
2
Strong authentication, encryption and approval for every path that can send commands.
3
Fallback paths, so monitoring and control survive the loss of one network.
4
Zones and conduits according to IEC 62443 and protected control protocols according to IEC 62351.
5
Inverters, controllers and gateways developed to the CRA, the Radio Equipment Directive and IEC 62443-4-2.
6
Playbooks for manual operation, reporting and recovery after an attack.
For operators and manufacturers, from the first applicability check to tested control paths.
Parks and substations that stay controllable under attack.
What we do
You receive
Zone model, measure plan, recovery plan
Clarity on NIS2, KRITIS, the CRA and the Radio Equipment Directive.
What we do
You receive
Applicability report, gap list, roadmap
Secure inverters, controllers and energy management systems.
What we do
You receive
Threat analysis, requirement set, architecture review
Evidence that devices and control paths withstand attacks.
What we do
You receive
Test report, response process, reporting playbook
Step 1
We agree on the sites, products and rules in scope.
Step 2
Site visits, workshops and a document review show where you stand.
Step 3
We create the work products with your engineers, or generate them with AITIGRITY.
Step 4
Tests, exercises and audit preparation close the gaps that matter.
Grid and generation operators are essential or important entities with duties for risk management and reporting. Operators of critical facilities also provide evidence to the BSI.
German grid and energy facility operators must meet the BNetzA IT security catalogues under the Energy Industry Act, including ISO 27001 certification.
Specific rules for cross-border electricity flows, with risk assessments for entities that are critical for the grid.
Security for power system communication, substation automation and the control systems and components in plants.
Inverters, controllers, wallboxes and gateways with digital elements fall under the CRA. Wireless devices have had to meet the RED cybersecurity requirements since August 2025.
The consulting services and AITIGRITY modules used most often in the energy sector.
A short scoping call shows which rules apply to your sites or products and what comes first.
Talk to an expertIn most cases yes, if they contain software or connect to networks. Wireless products must also meet the Radio Equipment Directive requirements. We check this per product family.
An information security management system with ISO 27001 certification for the scope defined in the catalogue, plus specific measures for the systems that control the grid or the plant.
With redundant communication paths, procedures for local and manual operation, and exercises that test them. We help you plan and practise this.
Yes. We review the security of remote control platforms and define the requirements your contracts should include.
Tell us about your product and the rule you are facing. You talk to an engineer from the first call.